  1. nassekova

    Blast City PSU and Amp Cap list / recap project

    Why? Is it prone to fail?
  2. nassekova

    Blast City PSU and Amp Cap list / recap project

    Is it 12v? Should this work? https://www.spelektroniikka.fi/p7415-tuuletin-12vdc-sunon-80-x-80-x-25-mm-fi.html Just have to take the power cable from the old one.
  3. nassekova

    Blast City PSU and Amp Cap list / recap project

    I just did full recap fo my friends Blast City PSU and Audio amp, thanks for the cap map! He had low audio issues so hopefully this fixes that. I think the ball bearings from the fan are busted so what fan have you guys used to replace the old one? Is the fan really necessary, does the...
  4. nassekova

    The best Street Fighter II Hack ?

    Not a "hack" related but I would like to get in to the series and I have CPS2 multi. So which Street Fighter game would be the best "intro to series" on that hardware? I read that SF 2 Turbo is ranked best, but it also seems to be the hardest? Might kill my enthusiasm if I can't beat the first...
  5. nassekova

    FS BetsuBetsu Streaming/recording audio+video splitter for JAMMA

    Finally got my back log of "stuff to fix" done so I made another 5 patch of these! Let me know if you need one, same old price. Tested and ready to go! Still 1st model since I bought components for lots of these years ago.
  6. nassekova

    Blast City grounding issue

    Yea I just disconnected the control panel earth ground cable and now there is no issues what so ever :thumbup:
  7. nassekova

    Blast City grounding issue

    Yes, those!
  8. nassekova

    Blast City grounding issue

    I tried to plug it other way but there is no difference. Still get the same 230V and 130V from the ground and other socket. I have two of these stepdowns and both of them have the same issue. These were pretty expensive and made for Japanese Hi-fi ehnthusiastics. Might be some kind of designs...
  9. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    Ahh ok, yea those give 0V AC when I measured them. I think the issue is this
  10. nassekova

    Blast City grounding issue

    I tried from my wall socket and with hot and ground I get 230V from there too. Only difference with the stepdown is that it gives 130V with neutral and ground where wall socket gives 0V. I have two of these stepdown transformers and both of these give that 130V with neutral and ground, so I...
  11. nassekova

    Blast City grounding issue

    I have this pretty beefy Stepdown and when I read it from the flat terminals it's about 100v BUT when I connect the multimeter to ground and either of the flat terminals I get either 130v or 230v And for the 2nd question, YES my control panel has continuity for my house ground.
  12. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    So should this give 0 VAC instead of 230V? Red probe is on ground. This is an old house (1952) and it still has couple of rooms without grounded wall outlets so there can be any kind of "wiring" done. Even my stepdown gives me 130V when connecting ground and other of the flat sockets. Or...
  13. nassekova

    Blast City grounding issue

    1. control panel and ground pin on the cabinet power cord HAS continuety 2. monitor frame and control panel DOES NO HAVE continuity.
  14. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    Made a new thread for my issue. Like I said, in the end it did not have anything to do with MiSTercade. https://www.arcade-projects.com/threads/blast-city-grounding-issue.28980/
  15. nassekova

    Blast City grounding issue

    Long story short, between my Blast CIty JAMMA ground, and cabinet ground (cables screwed to the floor) goes 170V AC live, and I would like to fix this. This whole thing started with MiSTercade remote, since I always got small electric shocks from the remotes metal casing when I touched it and...
  16. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    Just confirmed with multimeter that I get 168V AC between my JAMMA ground from the JAMMA edge and Blast City cabinet floor ground, so I will move this problem to another thread.
  17. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    And I just tested with my Tekken cabinet (found ground inside it from the metal plate where counters etc are) and there is no voltages between the MiSTercade remote and that ground. Continuity gives *peep* that both are ground. So this problem has probably nothing to do with MiSTercade, it was...
  18. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    It made no difference even when I took the MiSTercade out of the cabinet. I still get that 170V AC from cabinets screws. It seems that cabinet it self uses 3 prong cable, so it should be grounded from the step-down transformer. All the cables that come from the CRT part seem to be in good...
  19. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    I'm from EU so sockets are 220v but this goes through 100v stepdown so yeah, this sounds like CRT chassis leak or something... I will try those steps that you provided later and lets see how it goes.
  20. nassekova

    MiSTerAddons MiSTercade - MiSTer for JAMMA cabinets

    OK so there is definitely something shady going on in here. I measured AC from MiSTercade remote ground to my Blast City screw and there is hot/live going in there. There is 170V AC running between them, thats why I have been getting shocked :D Control panel grounding looks pretty normal...
Back